background image

FI

3

RST

DOOR / LID AJAR ALARM

The door/lid alarm will activate if it is ajar for more than five (5)
minutes. The control panel will beep every five (5) seconds, the red
alarm light will glow and the display will alternate between “d”
(DOOR/LID) and the cabinet temperature (see figure 7). Press the
ALARM RESET button to turn the audible alarm (beep) off. The
display will keep flashing and the red light will stay on. Close the
door/lid of the freezer to return it to normal operation.

POWER FAILURE

If power to the freezer is lost, the power loss alarm will activate. The
display will be off but the control panel will beep every minute (see
figure 8). To turn the audible alarm (beep) off, press the ALARM
RESET button. The audible alarm will also turn off automatically
when power is reconnected to the freezer. The temperature alarm
will activate if the temperature of the cabinet rises to al level above
23ºF (-5ºC) during power failure. The red alarm light however, will
not illuminate.

SYSTEM ERROR ALARM

The display will alternate between temperature and “CE” or “E”
and the control panel will beep every five (5) seconds (see figures
9 and 10). Press the ALARM RESET button to turn the audible
alarm (beep) off. Call service repair to correct the problem.

ALARM FUNCTION TABLE

Except during power loss, the red alarm light illuminates
whenever there is an alarm status.

Display Status

 

Function

 

Response

 

Cabinet 
temperature is 
displayed. 

Normal 
Operation 

None 

FF is displayed. 

Extreme Freeze 

None 

Temperature 
flashing on and 
off. Control panel 
beeps every 5 
seconds. 

Freezer 
temperature too 
high 

Check power is 
connected. 
Contact service 
technician. Press 
ALARM RESET to 
shut off audible 
alarm (beep). 

Alternating: “d” 
and temperature. 
Control panel 
beeps every 5 
seconds. 

Door ajar 

Close door. Press 
ALARM RESET to 
stop audible alarm 
(beep). 

Alternating: “E” 
and temperature. 
Control panel 
beeps every 5 
seconds. 

Operational error 

Contact service 
technician. Press 
ALARM RESET to 
stop audible alarm 
(beep). 

Alternating: “CE” 
and temperature. 
Control panel 
beeps every 5 
seconds. 

Operational error 

Contact service 
technician. Press 
ALARM RESET to 
stop audible alarm 
(beep). 

Display off. 

Power failure 

Reconnect power 
connection. 

Display Lock/Unlock: Press and hold ALARM RESET until the
control panel beeps to lock or unlock the display.

Figure 7

Figure 8

Figure 9

Figure 10

Summary of Contents for GLFU2067FW2

Page 1: ...Freezer Electronics Control Guide Congelador La Guía del Control de la electrónica Congélateur Le Guide de Contrôle d électronique 297088700 Feb 06 READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...room temperature food into a 15 cubic foot freezer To activate the Extreme Freeze feature push the Extreme Freeze button The control panel will beep once and the display will now read FF indicating that Extreme Freeze has begun see figure 4 For your convenience Extreme Freeze will automatically turn off after a period of 72 hours and the freezer will return to the previous temperature setting You ...

Page 3: ...ntrol panel will beep every five 5 seconds see figures 9 and 10 Press the ALARM RESET button to turn the audible alarm beep off Call service repair to correct the problem ALARM FUNCTION TABLE Except during power loss the red alarm light illuminates whenever there is an alarm status Display Status Function Response Cabinet temperature is displayed Normal Operation None FF is displayed Extreme Freez...

Page 4: ...ador de 15 pies cúbicos 0 42 m3 Paraactivarlafuncióndecongelaciónextrema oprimalatecla EXTREME FREEZE congelación extrema El panel de control emitirá una señal sonorayelindicadorvisualdesplegará FF paraindicarquelacongelación extrema ha sido activada vea la Fig 4 Para su mayor conveniencia la congelación extrema se apagará automáticamente después de 72 horas y el congelador regresará a su ajuste d...

Page 5: ...CIONES DE ALARMA La luz roja de alarma se enciende cada vez que existe una condición de alarma excepto durante una falla eléctrica Bloqueo desbloqueo de la pantalla Para bloquear o desbloquear la pantalla oprima y mantenga oprimido el botón ALARM RESET restablecer alarma hasta que el panel de control emita una señal sonora Figure 9 Figure 10 Figure 7 Figura7 Figure 8 Figura8 Figura9 Figura10 Indic...

Page 6: ...ésactiver le verrouillage du tableau de commande Le verrouillage permet d éviter de changer accidentellement les réglages de température et de congélation extrême L0C s affiche pendant trois 3 secondes pour indiquer que le tableau de commande est verrouillé figure 5 Une fois le verrouillage activé L0C s affiche pendant trois 3 secondes à chaque fois que vous appuyez sur une touche Lorsque le verro...

Page 7: ...cinq 5 secondes le témoin rouge d alarme s allume et l affichage indique tour à tour d et la température de la caisse figure 7 Appuyez sur le bouton ALARM RESET pour arrêter le bip sonore L affichage continue à clignoter et le témoin rouge reste allumé Fermez la porte le couvercle pour que le fonctionnement redevienne normal PANNED ÉLECTRICITÉ Si l alimentation du congélateur est coupée l alarme d...

Page 8: ...issauga Ontario Canada L5V 3E4 Electrolux Major Appliances North America Or O Ou Visit Frigidaire s Web Site at Visite la página de Frigidaire en Internet Visitez le site Internet de Frigidaire au http www frigidaire com The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use combined More than 55 million Electrolux Group products such as ref...

Reviews: