FAULT
POSSIBLE REASONS
HANDLING
Power cord not plugged in.
Plug it in.
The ICM does
not work.
No power coming through
the socket.
Check for fuse on the mains
Wrong EMS set point
Lower the set point as follows:
Press the "set" button, then
keep the “down" button
pressed until the you reach
the desired value, and then
press the "set" button again.
The ICM has recently been
reloaded with warm
products. It takes 11-18
hours to cool them down.
Preferably, reload the ICM
before night closing.
The ICM is loaded in such a
way that the air-circulation in
the interior is getting
blocked.
Load the ICM according to the
standards you have been
provided with by the company.
The condenser is blocked.
Dust has accumulated on the
condenser.
Clean the condenser using a
vacuum cleaner.
The door has been left open.
Press the defrost button and
defrost manually.
The door does not seal
properly.
Call a Service technician
The ICM does
not cool
properly. The
products are
warm.
Leakage in the cooling
system.
Repair the leakage (this type
of repair should be performed
by an authorized technician)
For this particular ice cold
merchandiser, a powerful
mechanism is needed and
consequently a certain
amount of noise cannot be
avoided.
Ice Cold Merchandisers are of
dynamic type, so a certain
amount of noise cannot be
avoided.
Intense metallic noise.
Call a Service technician
The ICM
sometimes
makes noise.
Inclined or curved floor.
Level the ICM properly by
adjusting its feet.