ENG
17
FOR AUTHORISED SERVICE PERSONNEL ONLY
APPENDIX A
HANDLING & TRANSPORTATION GUIDELINES
The merchandiser should always be transported:
•
in upright position (unless otherwise authorized by the supplier)
•
with the doors closed and stoppers for the sliding door models
•
on appropriate vehicles (e.g. with air shock absorbers and tail lift) and
from appropriate roads
•
strapped on a pallet ensuring proper protection of the cooling
mechanism
•
packed and stored properly, ensuring proper protection of the cooling
mechanism
•
Cooler temperature during storage or transportation should not be
below -20
o
C or above +60
o
C
APPENDIX B
PREVENTIVE MAINTENANCE GUIDELINES
PRIOR TO ANY CLEANING (INSIDE OR OUTSIDE THE DEVICE) OR
MAINTENANCE PROCEDURE, UNPLUG THE ICM! REMOVE THE PLUG AND
MAKE SURE THAT THE OPERATOR CAN CHECK FROM ANY OF THE
POINTS WHICH HE HAS ACCESS THAT THE CABLE IS UNPLUGGED.
It is mandatory that the Customer performs the following operations during the Preventive
Maintenance of an ICM once or twice a year, using a vacuum cleaner:
•
Cleaning of the condenser
•
Cleaning of the dust filters (if applicable).
If the ICM is placed in an environment where dust is accumulated on the condenser, then the
condenser has to be cleaned more often.
Additionally it is recommended that the following operations are carried out during preventive
maintenance:
1. Mechanical system:
•
Check that the equipment is correctly positioned and leveled.
•
Check that the front and back grid are fixed in place.
•
Check the self-closing system of the door.
•
Check that the fan support and fan grid are fixed in place.
•
Check the draining system and unclog if necessary.
2. Electrical system:
•
Check the power cable (replace if needed).
•
Check the illumination system.
•
Check the electrical connections.