MUTE / UP button: Mute Buzzer (i.e. open door alarm)
: DAY-NIGHT * button: For switching between Normal or Economy Mode
: Light Button / DOWN: Light Button for Activation-Deactivation of the Light
: Compressor icon display (when the compressor relay in the controller is activated)
: Fan icon display (when the fan motor relay in the controller is activated)
: Defrost icon display
Keypad
ECO mode: pushing the keypad at least 2 seconds the ECO mode will toggle (if ECO mode is running
then it will end, if ECO mode is waiting then it will start).
EcoBox Alarm Signals
“E0”
Regulation probe fault
“E1”
Evaporator probe fault (if available)
“dF”
Alternated to regulation probe temperature in Defrost
“dor”
Door open time-out
“Err”
Refrigerant System Failure Alarm
“ECO”
Alternated to reg. Probe temp. in Night mode
“CCP”
Alternated to reg. Probe temp. in CCP mode
When buzzer is On, it can be muted by pushing the button “BUZZER MUTE”.
5.
PRCD*
The PRCD device is integrated to the power cord of the unit, close to the wall plug.
The PRCD device features two buttons; the small one is the “test” button and is used to check the
operational status of the PRCD. The bigger button is the “reset” and is used to rearm the PRCD after a
triggering event.
*