ENG
24
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
Keep the glass door of the cooler closed during maintenance. If the
compressor needs to be replaced, you may need to use adequate
support to stabilize the cooler.
EASYREACH EXPRESS [R290] is equipped with HC refrigerant,
and has been tested and proven to be safe according to related
standards.
All necessary actions for safe usage & maintenance of this
appliance are described in this manual. Read carefully before
using the appliance and follow all precautions included in this
manual.
To reduce the possibility of fire, this appliance must be installed
only by a suitably qualified person.
If the cooler is not performing or not working at all before calling the authorized service provider,
please check the following.
FAULT
POSSIBLE REASONS
HANDLING
The unit does not
work.
Power cord not plugged in.
Plug it.
No power coming in the socket.
Check for fuse / MCB on the
mains.
The unit does not cool
enough or at all. The
products are warm.
The unit has recently been
reloaded with warm products. It
takes 8-16 hours to cool them
down.
Preferably, reload the unit before
night closing.
The unit is placed near strong air
streams or heat sources.
Relocate the unit according to
the instructions.