Levelling the Unit
Place the unit on the chosen spot. Use a spirit level to check whether the unit is levelled on both
directions. The spirit level can be placed on one of the shelves. If not, level the unit by adjusting the
levelling feet placed at the four corners of the base (a 32mm wrench will be needed for this operation).
It is essential that the unit is levelled during operation so as to avoid possible ice formation on the
evaporator’s fins due to insufficient drainage of the condensates.
3.2.3
Installation of the Shelves
The Easyreach Express is equipped with two shelves. These shelves form the two of the total three
loading levels on the unit. The shelves have different dimension in depth.
It is very important that the narrower rack is placed above the wider one.
If not, the unit’s performance will be severely affected, as the air curtain
will be disrupted.
To adjust the shelf, you must first unload it. Then, lift
and remove the shelf base plate and follow the steps
below:
1.
lift the shelf support from its back end,
2.
tilt slightly forward,
3.
pull to remove.
Place at the desired position by repeating the same
steps in the reverse order.
The unit is now ready to operate
3.3
Connection to the mains supply
Connect the ICM to a 220-240 Volts power supply on a 10A-16A fused & grounded socket.
Do not use extension cables.
Do not connect the merchandiser to:
a non grounded wall socket or power line
improper supply voltage and frequency
power supply that does not comply with the safety regulations of the
appliance or with current legislation on electrical installations