UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE 
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE 
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE 
HAS ACCESS THAT THE CABLE IS UNPLUGGED.

 

 

After maintenance operations, make sure that the grounding 
connections are in place before assembling the covers. Make sure 
you use the same fastening components and covers.

 

 

If any electrical components need to be replaced, use only the 
identical components in the spare part list supplied by the technical 
service department of Frigoglass. 

 

Keep the glass door of the cooler closed during cooling mechanism 
maintenance. The appliance will not stand stable when the 
compressor is disassembled. If the compressor needs to be 
replaced, use adequate support to stabilize the cooler.

 

 

After maintenance operations make sure that the strain relief, which 
supports the supply cord, is assembled properly.

 

 

If the ICM is not functioning properly or is out of order, please check the following before calling the 
authorized service provider: 
 

FAULT 

POSSIBLE REASONS 

HANDLING 

The ICM does not 
work.

 

Power cord not plugged in. 

Plug it in. 

No power supply at the socket. 

Check the outlet fuse. 

The cooler does not 
cool. 

 

The ICM has recently been reloaded 
with warm products. Please note 
that it takes some time to cool warm 
products. 

Preferably, reload the ICM before night 
closing. 

The ICM is loaded in such a way 
that the air circulation in the interior 
is getting blocked. 

Load the ICM according to the 
standards you have been provided 
with by the company. 

The door does not seal properly. 

Repair the doors for proper closing 
(this type of repair should be 
performed by an authorized 
technician). 

Leakage in the cooling system. 

Repair the leakage (this type of repair 
should be performed by an authorized 
technician). 

 
 
 
 

FAULT 

POSSIBLE REASONS 

HANDLING 

The ICM makes 
noise.

 

Intense metallic noise. 

Call a Service technician. 

Inclined or curved floor. 

Level the ICM properly by adjusting its 
feet. Placing a spirit level on the top of 
the ICM will assist you in leveling it. 

Summary of Contents for Flex 56 B HC

Page 1: ...ENG Flex 56 B HC Flex 65 B HC Flex 65 B ECO HC ...

Page 2: ...iginally written in English Before using this ICM please read the instructions below carefully Please see below the interpretation of the symbols used throughout the manual for your better understanding WARNING INFORMATION CAUTION FIRST AID ...

Page 3: ...nstallation operation 5 3 1 ICM placement instructions 5 3 2 Connection to the mains supply 6 3 3 Operation instructions 6 4 Care cleaning 7 5 Troubleshooting 7 6 First aid 9 7 Disposal of the unit 9 8 Recycling information 9 9 Warranty 10 APPENDIX A Handling transportation guidelines 11 APPENDIX B Preventive maintenance guidelines 11 APPENDIX C Guidelines to prevent corrosion of the cabinet 12 ...

Page 4: ...16A The outlet must be easily accessible for the purposes of installation and servicing 2 2 Climate classification According to climate specifications models Flex 56 B HC Flex 65 B HC and Flex 65 B ECO HC are Class 4 as per ISO23953 2 which means ambient temperature of 32 2 C and 65 humidity 2 3 Technical specifications Rating Voltage 220 240V 50Hz Defrosting Automatic 2 4 Physical dimensions Mode...

Page 5: ... use electrical appliances inside the food storage compartments of the appliance unless recommended by the manufacturer If the supply cord is damaged it must be replaced by the manufacturer its service provider or similarly qualified persons in order to avoid a hazard Do not place the merchandiser in direct sunlight or near heat sources radiators stoves other heating equipment outdoors without pro...

Page 6: ...ower line improper supply voltage and frequency power supply that does not comply with the safety regulations of the appliance or with current legislation on electrical installations If the mains cord supplied is not long enough do not use an extension lead Ask an authorized electrician to replace the cord with a longer one only if this is described in the list of authorized spare parts Do not plu...

Page 7: ...r to avoid mould formation odours etc product compartments must also be thoroughly cleaned The interior of the ICM should be cleaned with a mildly soapy cloth and the glass surface using a window cleaning agent In case the merchandiser is placed in very dusty and or greasy environment the regular cleaning of the condenser by an authorized technician is mandatory Keep the cooler in a stable positio...

Page 8: ...ioning properly or is out of order please check the following before calling the authorized service provider FAULT POSSIBLE REASONS HANDLING The ICM does not work Power cord not plugged in Plug it in No power supply at the socket Check the outlet fuse The cooler does not cool The ICM has recently been reloaded with warm products Please note that it takes some time to cool warm products Preferably ...

Page 9: ... minutes and then consult a doctor Contact with skin Wash immediately with water 7 Disposal of the unit For detailed information regarding the recycling of this product please contact your local city office your waste disposal service or the manufacturer through its service agent By ensuring this product is disposed of properly you will help prevent potential negative consequences for the environm...

Page 10: ... are not recycled raw materials have to be processed for the production of new products This represents significant loss of resources as the energy transport and environmental damage caused by these processes is considerable To help in the recovery and recycling process of this appliance do not dismantle or break parts off the appliance prior to collection By removing parts off the appliance you c...

Page 11: ...of an ICM once or twice a year using a vacuum cleaner Cleaning of the condenser Cleaning of the dust filters if applicable If the ICM is placed in an environment where dust is accumulated on the condenser then the condenser has to be cleaned more often Additionally it is recommended that the following operations are carried out during preventive maintenance 1 Mechanical System Check that the equip...

Page 12: ...troller and its components are functioning properly Check the cooling performance of the ICM Check the cooling circuit using the appropriate leak detector in case there is any concern or sign of refrigerant leak APPENDIX C GUIDELINES TO PREVENT CORROSION OF THE CABINET 1 Avoid damages resulting from improper installation operation improper maintenance cleaning as well as improper handling and tran...

Page 13: ...s 30 210 6165700 NORWAY FRIGOGLASS NORDIC AS Kampenes Industriomrade Bredmyra 10 12 1740 Borgenhaugen 47 69111800 POLAND FRIGOGLASS SP ZO O Lazy ul Waska 3 05 552 Wolka Kosowska 48 22 711 46 00 ROMANIA FRIGOGLASS ROMANIA SRL DN 59 Timisoara Moravita KM 16 307396 Parta Timis 40 256407530 RUSSIA FRIGOGLASS EURASIA LLC Kursovoy Pereulok 9 119034 Moscow 70 959807780 TURKEY SFA Sogutma Sanayi Ic ve Dis...

Reviews: