ENG
13
5. Troubleshooting
ALL ACCESS TO THE COOLING SYSTEM AND ELECTRICAL PARTS
(CHANGING A LAMP OR REFRIGERATION DECK) MUST BE PERFORMED
BY AUTHORIZED PERSONNEL ONLY
.
Models ICM2000 [R290] & Slim HC are equipped with HC
refrigerant. All service operations on cooling mechanism & gas
charging should be performed in a well ventilated environment
or in open air. Do not smoke during maintenance.
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE HAS
ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
Keep the glass door on the back side of the cooler closed during
maintenance. The appliance will not stand stable when the
compressor is disassembled. If the compressor needs to be
replaced, use adequate support on the front side of the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
POSSIBLE REASONS
HANDLING
The ICM does not
work.
Power cord not plugged in.
Plug it in.
No power coming through the
socket.
Check for fuse/MCB on the mains.
The cooler does not
cool enough. The
products are warm.
The thermostat setting is not correct. Rotate the thermostat knob clockwise.
The ICM has recently been reloaded
with warm products. It takes 8-16
hours to cool them down.
Preferably, reload the ICM before night
closing.
The ICM is loaded in such a way
that the air circulation in the interior
is getting blocked.
Load the ICM according to the
standards you have been provided
with by the company.
The door does not seal properly.
Repair the doors for proper closing