If one or more of the bottles break while in the appliance and liquid spills
inside the cabinet or the space surrounding the appliance gets wet,
unplug the cooler before you clean the liquid around and inside the
cooler. Remember to take all necessary actions to protect yourselves
from broken glass (use protective gloves when cleaning).
9. Troubleshooting
ALL ACCESS TO THE COOLING SYSTEM AND ELECTRICAL PARTS
(CHANGING A LAMP OR REFRIGERATION DECK) MUST BE PERFORMED
BY AUTHORIZED SERVICE PERSONNEL ONLY.
MAX-450 [R290] C, MAX-700 [R290] C, MAX-900 HD [R290] C,
MAX-1000 HD/SD [R290] C are equipped with HC refrigerant. All
service operations on cooling mechanism & gas charging
should be performed in a well-ventilated environment or in open
air. Do not smoke during maintenance.
•
UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
•
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
•
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
•
Keep the glass door of the cooler closed during cooling mechanism
maintenance. The appliance could be unstable when the compressor
is disassembled. If the compressor needs to be replaced, use
adequate support to fix the cooler.
•
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
POSSIBLE REASONS
HANDLING
The ICM does not
work.
Power cord not plugged in.
Plug it in.
No power coming through the
socket.
Check for fuse/MCB on the mains.