UNPLUG THE COOLER PRIOR TO ANY MAINTENANCE OR SERVICE
OPERATIONS. REMOVE THE PLUG AND MAKE SURE THAT THE
OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE
HAS ACCESS THAT THE CABLE IS UNPLUGGED.
After maintenance operations, make sure that the grounding
connections are in place before assembling the covers. Make sure
you use the same fastening components and covers.
If any electrical components need to be replaced, use only the
identical components in the spare part list supplied by the technical
service department of Frigoglass.
Keep the glass door of the cooler closed during cooling mechanism
maintenance. The appliance could be unstable when the compressor
is disassembled. If the compressor needs to be replaced, use
adequate support to fix the cooler.
After maintenance operations make sure that the strain relief, which
supports the supply cord, is assembled properly.
If the ICM is not functioning properly or is out of order, please check the following before calling the
authorized service provider:
FAULT
POSSIBLE REASONS
HANDLING
The ICM does not
work.
Power cord not plugged in.
Plug it in.
No power coming through the
socket.
Check for fuse/MCB on the mains.
The cooler does not
cool enough. The
products are warm.
The thermostat setting is not correct. Rotate the thermostat knob clockwise.
The ICM has recently been reloaded
with warm products. It takes 8-16
hours to cool them down.
Preferably, reload the ICM before night
closing.
The ICM is loaded in such a way
that the air circulation in the interior
is getting blocked.
Load the ICM according to the
standards you have been provided
with by the company.
The door does not seal properly.
Repair the doors for proper closing
(this type of repair should be
performed by an authorized
technician).
Leakage in the cooling system.
Repair the leakage (this type of repair
should be performed by an authorized
technician).
The ICM sometimes
makes noise.
For this particular ice cold
merchandiser, a powerful
mechanism is needed and
consequently a certain amount of
noise cannot be avoided.
Ice Cold Merchandisers are of
dynamic type, according to the
specifications that the company is
offering.
Intense metallic noise.
Call a service technician.
Inclined or curved floor.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.