ENG
11
Note: Relocation of the ICM inside the outlet
a. Empty the ICM and unplug from mains supply.
b. Fully extract the leveling feet.
c. Move the unit to the desired location with the assistance of another person.
3.2 Shelf installation instructions
To adjust the shelf first unload it, lift it and unclip the shelf clips (4). Place the clips in the desired
position and reposition the shelf. Make sure that the horizontal metal rods at the bottom of the shelf
are between the front and back shelf clips, as shown below.
Note: Specifically, the Smart-450L, 500 & 800 models are each equipped with 4 shelves with spacers
(on the back side) and one shelf without spacer.
The shelf without spacer has to be placed on top level in order to fit with the additional metal part for
air circulation, as shown in below pictures.
Note: When using the optional front visibility shelving system, please follow the installation instructions
included in the shelving kit.
3.3 Connection to the mains supply
Connect the ICM to a 220-240 Volts power supply on a 10-16A fused & grounded socket. Do not use
extension cables.
Do not connect the merchandiser to:
a non grounded wall socket or power line
improper supply voltage and frequency
power supply that does not comply with the safety regulations
of the appliance or with current legislation on electrical
installations
Additional metal part
Shelf with spacer
Shelf without spacer