ENG
6
Do not operate the merchandiser if the front or back, grilles and
fans’ enclosures are removed or not properly attached.
Before selecting the placement location for your merchandiser you
must read the information about IP protection degree in the name
plate attached to the internal wall of the Cabinet. Outdoor
installation is only allowed for refrigerated cabinets with IP24
degree of protection. For lower degree of protection outdoor
placement of the unit is prohibited.
4. Installation & operation
Failure to comply with the instructions may result in high-energy
consumption, poor performance of the unit and void warranty.
4.1 Installation instructions
i.
After unpacking, check the cabinet for any damage caused during transportation. In the event of
damage, please contact the forwarding company.
ii.
Always ensure that your merchandiser is installed on a stable surface/floor and is properly
leveled. There are 2 adjustable feet at the front, under the chassis. Please, adjust until the ICM
levels and check using a spirit level, if available.
Do not place the merchandiser:
in direct sunlight or near heat sources (radiators, stoves & other
heating equipment)
outdoors, without proper protection from rain, moisture and other
atmospheric elements
in weather conditions for which it is not certified
in extreme environmental conditions (i.e. extensive exposure to
saline humidity)
on a surface with an angle more than 5
o
Mains connection: if the mains cord supplied is not long enough, do not use an extension lead and do
not replace it. Ask an authorized electrician to replace the cord with a longer one.
iii.
The merchandiser must stand upright for at least 1 hour after transportation and prior to start-up.
This gives the oil time to run back to the compressor after transit and installation.
iv.
Allow a minimum gap of 100mm at the top, 100mm at the rear and 50mm at the sides of the
cooler for proper ventilation. Do not place anything on top of the cooler.
Keep the ventilation openings, both in the appliance enclosure and in the
built-in structure, clear of obstruction.