ENGLISH - 18
6. Slide the agitator and the stuffing box out.
7. Disassemble the outlet door, unscrew in
counterclockwise the two fixing knob. Remove the
outlet door gasket.
8. Wash all components previously described with a
detergent/sanitizer solution. Let them dry in the
open air.
9. Accurately sanitize the cooling cylinder.
10. Remove the drip drawer from the front panel and
thoroughly wash it. If the drip drawer contains
some mixture, the agitator stuffing box is leaking
and shall be replaced.
11. Lubricate the OR rings and the stuffing box with
FRIGOMAT lubricant for food industry only, which
is provided as standard. Once a week, it is
advisable to rotate the agitator stuffing box so that
the rubber elasticity can be recovered.
- For cleaning the cylinder after removing the
agitator, it is necessary to close the hole in the
bottom using the plug in outfit.
- To preserve plastic components and gaskets,
never use solvents and/or diluents during washing.
- Sanitizing chemicals shall be used according to
laws in force and with the utmost caution.
- After any sanitizing operation, it is indispensable
not to touch the sterilized parts either with hands
or with towels, sponges or other.
- Avoid making the agitator run empty, as the
machine can be damaged.
Summary of Contents for VIBE-GEL 05 Series
Page 1: ......
Page 3: ...1 ITALIANO ...
Page 29: ...1 ENGLISH ...
Page 55: ...1 FRANÇAIS ...
Page 81: ...1 DEUTSCH ...
Page 107: ...1 ESPAÑOL ...
Page 137: ...5 APPENDICI VIBEGEL s05 TAV 1 8 ...
Page 139: ...7 APPENDICI VIBEGEL s05 TAV 2 8 ...
Page 141: ...9 APPENDICI VIBEGEL s05 TAV 3 8 ...
Page 143: ...11 APPENDICI VIBEGEL s05 TAV 4 8 ...
Page 145: ...13 APPENDICI VIBEGEL s05 TAV 5 8 ...
Page 147: ...15 APPENDICI VIBEGEL s05 TAV 6 8 ...
Page 149: ...17 APPENDICI VIBEGEL s05 TAV 7 8 ...
Page 151: ...19 APPENDICI VIBEGEL s05 TAV 8 8 ...
Page 153: ...NOTE NOTES NOTES BEMERKUNG NOTA ...
Page 154: ......