TROUBLESHOOTING

 

 

Any trouble occurring might be due to a minor problem that you can correct yourself following 
the instructions below. Do not try any further action if the pointers given cannot solve the 
problem! 

 

Repairs on the cabinet must be made only by a qualified refrigeration engineer.  Incompetent 
repair work can cause serious personal danger: contact your service organisation for any 
repairs needed.

 

 

Cabinet does not work (no audible running noise or only fan noise audible 

 

Possible Cause: 
a)

 

automatic evaporator defrosting active or 

thermostat switched off 

b)

 

power plug not connected 

c)

 

fuse blown, power plug or socket defective 

 

d)

 

condenser fins dirty

 

 

Corrective Measure: 

None: cooling will automatically 
switch on again

 

Insert plug properly. Switch ON 
Contact your electrician or service 
organisation

 

Contact service organisation for 
maintenance

 

Storage Temperatuere too high

 

 

 

a)  automatic defrosting active

 

None: Temporary minor temperature

 

rise during defrosting is normal

 

b)   ambient temperature too high or

 

Avoid extreme operating

 

 

`

environment i.e temperature over 25

°

Adjust storage temperature-controller

c)  distance to wall not adhered

 

Maintain presribed minimum distance

c)    lack of air intake due to

Remove any obstacles in air intake

obstruction of grill

 

area

d)   condenser fins dirty

 

Contact engineer to perform

 

 

maintenance

Storage Temperature too low

 

a)  misadjustment

 

Adjust storage temperature in small

 

increments

Cabinet lighting failed

 

a)  lighting not switched on

Switch lighting on

 

b)  the starter or light fitting is defective

 

 

R

eplace starter or complete fitting

Heavy Condensation in Display Area 

Extreme ambient temperature – relative humidity                

Improve operating environment.

 

is more than 60% or very high summer temps                    

install air  onditioning to reduce

 

room temperature to below 25

° 

C

 

 

Water under or in front of cabinet 
a)  automatic defrosting defective                                                  

Wipe water off.  If new water forms

 

b)extreme operating environment. Relative                                   

within the next 48 hours contact your

 

humidity over 60% or high summer temperatures                         

service organisation

 

causes overflow of drip tray 

 

Formation of Odour in Cabinet 
a)

 

Spaces under return air grill dirty                                              

Clean

 

b)

 

Drain pipe blocked                                                                    

Remove blockage

 

c)

 

Spillage                                                                                      

Clean

 

 

 

In the interest of continual product development we reserve the right to change any of the 

details and specifications without notice. 

Page 16 

Summary of Contents for FBC-601

Page 1: ... mentioned product groups only prepacked products with the following temperatures may be stored Proper use only means the use as described above adhering to the specifications on installation operation and service Any other use is regarded as being contrary to specifications and is prohibited The Buyer responsibility to insure that the equipment will be fit for the purpose for which the Buyer inte...

Page 2: ...display Frequently while on display Minimum core temp of 63 C Cold food on display Frequently while on display 0 to 7 C is recommended The chart above gives the temperatures that are generally accepted as good practice together with the recommended period of time involved where appropriate Keeping food at these temperatures plays a major part in ensuring that food is safe to eat Do not leave food ...

Page 3: ... working or safety of your plug in refrigerated cabinet When disconnecting the power plug always pull on the plug itself and never the cable Never detach any cover except where specifically instructed in this manual Doing so might expose live electrical parts If any damage occurs to the power cable pull the plug to disconnect the cabinet Never use a water hose or high pressure jet to clean the cab...

Page 4: ...k Adhere to the specific minimum distance of 80mm When the cabinet is installed as a stand alone unit against a wall a minimum distance of 80mm must be maintained between cabinet back and room wall to ensure free air exit on the cabinet back When installing several cabinets alongside or behind one another be sure to observe the specific installation plan In all installation options the air exit mu...

Page 5: ...accessories it must be left to stand for at least three hours before being started to allow the lubricating oil to settle in the compressor Failure to do so can cause total destruction of the refrigeration system Ensure the means of transporting positioning used does not damage elements which exist in the lower part of the equipment Start the cabinet only if it has been installed as described and ...

Page 6: ...ng conditions The units are delivered with the regulation already factory set All temperature and defrost regulations must be set by a qualified refrigeration engineer The buyer responsibility to ensure that the equipment will be fit for the purpose for which the Buyer intend to use the equipment ADJUSTING THE CONTROLLER Please refer to the specific controller instructions included In the interest...

Page 7: ... slightly Defrost frequency as well as duration and time are factory set Defrosting is automatic four times a day All cabinets have a stainless steel drip tray with an electrical heating element operated by a float switch and a hot gas pipe running under the tray to evaporate the condensate water In the interest of continual product development we reserve the right to change any of the details and...

Page 8: ...nsfer it to another storage place Do not start cleaning before the internal surfaces have risen to near room temperature take accessories out of display compartment unscrew 2 recessed head screws at the return air grill with a screwdriver pull out return air grill backward of the fixing device No cleaning water must be allowed to flow into the defrost water drain moisten cotton cloth with luke war...

Page 9: ...ional faults are detected check the electrical protection and switches to make sure they are in perfect condition If the fault persists advise the maintenance contractor Cleaning the condenser fins The refrigerated cabinet must be maintained by a qualified refrigeration engineer every three months and in addition the condenser fins need cleaning by a qualified refrigeration engineer whenever a lay...

Page 10: ...d regularly supervised and maintained in a satisfactory manner b the parties concerned shall also be responsible when the system is used by another person unless a division of responsibility has been agreed upon c regular maintenance or adjustment of the refrigerating system can only be carried out by a qualified refrigeration engineer maintenance shall be carried out every three months by a quali...

Page 11: ...ollowing tasks shall be performed a all safety control and measurement devices as well as alarm systems shall be checked to verify their correct operation and perfect working order b leakage tests shall be carried out at the relevant part of the refrigerating system c evacuating d adjustment of refrigerant charge e functional test of safety devices Maintence and repair requiring the assistance of ...

Page 12: ...ING For applications designed to be used with flammable refrigerants it is necessary to perform an evaluation of the risk involved with the usage of this refrigerant The equipment manufacturer should perform a risk assessment and ensure proper knowledge about the handling and use of any flammable refrigerant prior to applying the compressor condensing unit WARNING Compressor condensing unit incorp...

Page 13: ...or condensing unit starting under vaccum or without refrigerant charge WARNING Use the compressor condensing unit only with the refrigerant indicated on compressor condensing unit label WARNING System refrigerant charge when using HC refrigerants R 600 a R 290 must be limited to 150 g max WARNING Use the compressor condensing unit only with the power supply indicated on the compressor condensing u...

Page 14: ...nents specified by the manufacturer WARNING On applications where flammable refrigerant is used do not weld the tubes by torch but connect the compressor condensing unit tubes by other means such as lock ring WARNING Before energizing the system check the compressor condensing unit grounding and make sure electrical components and covering are fixed properly WARNING Connect the equipment only to a...

Page 15: ...net is to be shut down for any length of time clean cabinet When stored in a storage room cover with a cotton sheet Do not use plastic tarpaulins as these may encourage formation of moisture and odours inside the cabine In the interest of continual product development we reserve the right to change any of the details and specifications without notice Page 15 ...

Page 16: ... 25 Adjust storage temperature controller c distance to wall not adhered Maintain presribed minimum distance c lack of air intake due to Remove any obstacles in air intake obstruction of grill area d condenser fins dirty Contact engineer to perform maintenance Storage Temperature too low a misadjustment Adjust storage temperature in small increments Cabinet lighting failed a lighting not switched ...

Reviews: