background image

|  

2

                            

User Instructions Low Temperature Freezers Model GLE

Livøvej 22 - 8800 Viborg - Tlf. 86 61 34 11 - www.frigor.dk

User Instructions  Low Temperature Freezers Model UNI/LT

2

USER INSTRUCTIONS

Congratulations on your new low temperature 
freezer. We trust that it will serve you for many years 
to come. In order to gain optimum benefit from 
your freezer, please read the following instructions 
thoroughly and act accordingly. The low-tempera-
ture freezers are used for freezing and long-term 
storing of food products, medical preparations ( 
vaccines, blood plasm, ect.) and other biological 
products.

1. Environmental protection and disposal.

The packaging is designed to protect the 
appliance and its components during 
transportation, and it is made of recyclable 
materials.
 

• Please return the packaging to an

 

   official collection point for recycling.

 

• Old appliances contain reusable

 

    materials and should not be disposed

 

   of together with household refuse.

 

• Remove the spring-action hinges from

 

   the appliance, in order to prevent

 

   children from being entrapped in the

 

   appliance.

 

• Ensure that no part of the refrigeration

 

   tubing is damaged as the refrigerant

 

   in the appliance risks escaping to the

 

   environment.

 

• Information about refrigerant type  

 

 

   and amount will be found on the type

 

   plate on the rear of the appliance

 

   (Fig. 1).

2. Safety instructions.

 

• In order to prevent injuries and or

 

   damage to the appliance, it should

 

   be unpacked and set up by min. two

 

   people.

 

• If upon unpacking the appliance is

 

   found damaged, do not connect to

 

   the mains, but contact the supplier.

 

• 

Interference with or repair to the

 

   appliance should only be carried out

 

   by authorized personnel, in order to

 

   avoid any injuries. (contact the sup-

 

   plier for further information).

 

• Never put naked flames or other igni-

 

   tion sources inside the appliance.

 

• Never touch the freezers interior or

 

   products in the freezer when the  

 

 

   freezer is operating. Use gloves or alike

 

   in order to avoid injuries (frost-bite).

 
 

• Keep the key to the appliance away

 

   from the appliance and out of the

 

   reach of children.

3. Connection to the mains.

 

• For safety reasons the appliance must

 

   be earthed. If you are in any doubt,

 

   please contact an authorized electri 

 

   cian.

 

• The appliance should be left for 5

 

   hours before it is connected to the

 

   mains. If the appliance is connected

 

   before that, there is a risk of damaging

 

   the compressor.

 

• If for any reason the appliance is

 

   disconnected from the mains, please

 

   wait 10 minutes before re-connecting.

 

   The electronic starting device needs

 

   this time to cool down, before a safe

 

   re-start can be made.

4. Before use.

 

• Before use, the interior of the appli-

 

   ance should be cleaned with a mild

 

   soap solution, and wiped off with a dry

 

   clean cloth. Never use any kind of

 

   solvent or other chemicals.

5. Setting up the freezer.

The freezer should not be placed where it 
might be splashed with water, in extreme 
high humidity or in direct sunlight. Any of 
these factors may lead to a reduction in 
performance and shorten the life span of 
the components. The freezer should be 
placed on a horizontal level, and should
not be placed close to a heating appliance 
or heating tubes. Allow a minimum of 50mm 
(2”) clearance on the side and the back. 
The side with the ventilation grill should have 
a clearance of at least 100 mm (4”) in order 
to allow the heat from the compressor
motor to dissipate. Underneath the appli-
ance there should be a gap of 15 mm ap-
prox. (1⁄2”). On a soft surface, e.g. carpet, 
it may be necessary to ensure the correct 
distance by means of spacers.

GB

Summary of Contents for GLE

Page 1: ...User Instructions Low Temperature Freezers Model GLE Livøvej 22 8800 Viborg Tlf 86 61 34 11 www frigor dk Low Temperature Freezers Model GLE User Instructions mODEL gle ...

Page 2: ...n order to avoid any injuries contact the sup plier for further information Never put naked flames or other igni tion sources inside the appliance Never touch the freezers interior or products in the freezer when the freezer is operating Use gloves or alike in order to avoid injuries frost bite Keep the key to the appliance away from the appliance and out of the reach of children 3 Connection to th...

Page 3: ...In order for the freezer to work to its maxi mum efficiency the cabinet should be de frosted when a approx 2mm thick ice layer has formed inside the cabinet The ice layer is easily removed with a plastic or wooden scraper Never use a sharp metal object which might will cause damage to the inner liner The defrosting frequency is determined mainly by two factors the usage pattern number of lid opening...

Page 4: ...safe storage of sensitive products In some situations the GLE freezer is also used for other applications like in laborato ries for different low temperature test Depending on the actual situation it might be necessary to change the controllers off set value in order to get a correspondence between the reading on the display and the actual temperature inside the cabinet The factory setting is an offs...

Page 5: ...e separated and far enough from each other without crossing or intertwining In case of applications in industrial environments the use of mains filters our mod FT1 in parallel with inductive loads could be useful GENERAL DESCRIPTION Model XR30C format 32 x 74 mm is a digital termostat with off cycle defrost designed for refrigeration applications at normal temper ature It provides two relay outputs ...

Page 6: ...taken place To see the kind of alarm the max min reached temperature and alarm duration do as follows 1 Push the Up or Down key 2 On the display the following mes sage is shown HAL for high temperature alarm LAL fot the minimum allarm followed by the Maximum mini mum temperature Then the tiM tiMe message is displayed followed by the Dura tion in h mm 3 Then the instrument displays the temperature ...

Page 7: ...eep pressed the Set n for more than 7s The Pr2 label will be displayed immediately fol lowed from the HY parameter NOW YOU ARE IN THE HIDDEN MENU 3 Select the required parameter 4 Press the SET key to display its value Now only the LED is blinking 5 Use o or n to change its value 6 Press SET to store the new value and move to the following parameter To exit Press SET o or wait 15s without pressing...

Page 8: ...elsius F Fahrenheit WARNING When the measurement unit is changed the SET point and the values of the parameters Hy LS US Ot ALU and ALL have to be checked and modified if necessary rES Resolution for C in 1 C dE 0 1 C allows decimal point display DEFROST IdF Interval between defrost cycles 0 120h Determines the time interval between the beginning of two defrost cycles MdF Maximum length for defrost...

Page 9: ...input is program mable in five different configurations by the i1F parameter DOOR SWITCH INPUT i1F dor It signals the door status and the corre sponding relay output status through the odc parameter no Fan normal any change CPr F_C Compressor OFF Since the door is opened after the delay time set through parameter did the door alarm is enabled the display shows the mes sage dA and the regulation resta...

Page 10: ... suitable external relay PROBE CONNECTION The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration It is recommended to place the thermostat probe away from air streams to correctly measure the average room temperature Place the defrost termination probe among the evaporator fins in the coldest place where most ice is formed far from heaters or from the ...

Page 11: ... Housing self extinguishing ABS Case XR30C frontal 32x74 mm depth 60mm Mounting XR30C panel mounting in a 71x29mm panel cut out Protection IP20 Frontal protection IP65 with frontal gasket RG C optional Connections Screw terminal block 2 5 mm2 wiring Power supply according to the model 12Vac dc 10 24Vac dc 10 230Vac 10 50 60Hz 110Vac 10 50 60Hz Power absorption 3VA max Display 3 digits red LED 14 2...

Page 12: ...alarm at start up Alarm relay silencing 2nd relay configuration Second relay polarity oA1 ALr Digital input polarity Digital input configuration Digital input delay Number of activation of pressure switch Compressor status with open door Kind of probe Software release Map code Label Name Range C F 3 0 37 2 0 4 50 0 58 110 230 0 0 0 1 0 0 15 30 CL ºC ºF dE 8 20 it 30 Ab LS US 0 1 25 5ºC 1 255ºF 50º...

Page 13: ...p Probe selection N A N A Label Set Hy LS US Ot Ods AC CCt COn COF CH CF ldF Mdf dFd dAd Alc ALU ALL Ald dAo PbC Rel Ptb Dixell XR30C 115 volt Setting Celcius 45 3 50 0 0 1 3 0 60 5 CL C 120 0 Set 1 Ab 36 50 120 24 Ptc 3 84 Setting Farenheit 45 3 58 0 0 1 3 0 60 5 CL F 120 0 Set 0 Ab 33 58 120 24 Ptc 3 84 230 volt Ambient temperature Gross volume Gross volume Height on feet Height with open lid Wi...

Page 14: ... Freezers Model GLE Livøvej 22 8800 Viborg Tlf 86 61 34 11 www frigor dk User Instructions Low Temperature Freezers Model UNI LT 14 Wiring diagrams Censor Power supply 230V 50 60 HZ Power supply 230V 50 60 HZ Censor GLE 10 20 30 40 GLE 50 ...