Service reports
46 / 59
V-09 - 03/2017 - PM/Stme - English - © FRIMA
Service report
Error
Effects and action
Service 110
Error in temperature
measuring system B1
Roasting applications possible
Model 112/112T/112L: No restrictions in the
right-hand pan
Call customer service
Service 111
Error in temperature
measuring system B2
Roasting applications possible
No restrictions in the left-hand pan
Call customer service
Service 121,... 128
Error in temperature
measuring system
B4, ... B11
Call customer service
Service 200
Flow sensor
Please check the water inlet.
Cooking without automatic water inlet
possible
Service 201
Hot water flow sensor
Please check the hot water inlet.
Cooking without automatic hot water inlet
possible
Service 220+222
Error in the locking
system
Model 112: No restrictions in the right-hand
pan
Call customer service
Service 221 + 223
Error in the locking
system (R)
No restrictions in the left-hand pan
Call customer service