3.
the indoor & outdoor humidity range: 20% --- 99%
6.4 Trend indicator indoor/ outdoor
a.
The temperature trend indicator is based on the difference between a recorded temperature and the current
temperature. When the current temperature is at least 1°C higher than the recorded, the arrow will point up and the current
temperature becomes the recorded.
If the temperature is at least 1°C lower than the recorded value, the arrow will point down and the current temperature
becomes the recorded. In all other cases, the arrow will be flat.
b.
The humidity trend indicator is based on the difference between a recorded humidity and the current humidity. When
the current humidity is at least 3% higher than the recorded, the arrow will point up and the current humidity becomes the
recorded.
If the humidity is at least 3% lower than the recorded value, the arrow will point down and the current humidity
becomes the recorded. In all other cases, the arrow will be flat.
c. The pressure trend indicator is based on the difference between a recorded pressure and the current pressure.
When the current pressure is at least 2mb higher than the recorded, the arrow will point up and the current pressure
becomes the recorded.
If the pressure is at least 2mb lower than the recorded value, the arrow will point down and the current pressure
becomes the recorded. In all other cases, the arrow will be flat.
raising
steady
falling
6.5 Indication of the comfort index
1.
Dry: when temperature range is any values, humidity range is under 40%
2.
Comfort: when temperature range is between 20
℃
to 28
℃
, humidity range is between 40% to 70%
3.
Wet: when temperature range is any values, humidity range is up 70%
4.
No indication: temperature range is less than 20
℃
and more than 28
℃
, humidity range is between than 40% to70%
COMFORT
ICON DISPLAY
TEMPERATURE
HUMIDITY RANGE
LEVEL
RANGE
DRY
-5°C
to
under 40 %
+50 °C
COMFORT
+20 °C
to
40% to 70%
+28 °C
WET
-5°C
to
Over 70%
+50 °C
Less than 20 °C
Less than 40% or
NO INDICATION
-
or
more
than
more than 70%
28 °C
6.6 The receiving function of RF