7 Control
choices
7.1 External
control
You may control the
SG-1300 or SG-1300-CASED
externally through the XLR sockets.
Please note
: DMX takes priority. That means: when the machine is controlled via 5-PIN DMX 512
this data takes priority over the 0-10 V (+) 3-PIN XLR Analog Remote and Stand-alone
operation.
7.2 Operating
via
DMX
512
Connecting the
SG-1300 or SG-1300-CASED
to a DMX-desk use the 5pin XLR socket . As soon
as the machine receives a correct DMX signal, the yellow DMX-LED shines. Now the pump can be
adjusted via the desk.
Adjusting the DMX start address
Press the Mode-button
at the control panel, until three figures will appear on the
LED display
Adjust the requested start address by pressing the Up/Down-buttons .
Save the start address by pressing the Enter-button once. The start address will also be
saved when you disconnect the machine from the mains supply.
Now the pump can be adjusted via the desk.
When you switch off the DMX signal, the machine will be switched off automatically after 15
seconds.
7.3 Stand-alone
The
SG-1300
can be used in the Stand alone mode. In this mode the control of the pump must be
adjusted at the machine.
Press and release the Mode-
button until a „P” and two figures appear on the display .