2.5.4 System 1 (hygienic layered tank / two heating circuits)
N
AUF
ZU
N
AUF
ZU
L
N
L1
N
L
N
Mischer 2
(30)
HKP 0 /
Brennerrelais
(34)
Heizkreis-
pumpe 1
(33)
Heizkreis-
pumpe 2
(32)
Mischer 1
(31)
PWM/0-10V
Pumpe 1 (26)
V
orlauf-
fühler 1 (23)
V
orlauf-
fühler 2 ( 22)
Durchfluss-
messer (12)
L
N
Netz
(29)
L
N
Pumpe 1
(28)
L
V
Fühler 1 (18)
Fühler 2 (17)
Betriebs-
signal
(35)
M
M
2
2
2
2
2
3
3
3
4
4
A
B
C
D
E
F
G
H
I
J
Fröling PECO
Pump assembly
OE
Hygienic layered tank H2
Flow temperature sensor 1/2
Heating circuit pump 1/2
Mot. mixing valve 1/2
Sensor 1, E
Sensor 2, J
Balancing
valve
Pumpe 1
Domestic hot water
Note:
Please install a mixing
valve to limit the outlet
temperature of the
domestic hot water.
Cold water
Hygienic layered tank H2:
Connections are
represented schematically.
If deviating from the default configuration, the following changes must be made:
❒ Select “System 1” in the system selection
❒ Deactivate DHW tank 01
❒ Activate heating circuit 02
⇨ See "Setting the system selection" [page 34]
Adjust sensor assignments:
❒ In the service menu of the storage tank, assign the sensor inputs according to the diagram shown above
NOTICE! The hot water preparation is implemented via the hygiene element of the layered tank. As no sensor
can be assigned, no DHW tank can be parameterised either. We recommend fitting some sort of control device
(e.g. thermometer with external sensor) for the domestic hot water temperature.
2
Power connection and wiring
Connection options with standard delivery
32
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com