3.3 Setting the system selection
❒ In the “system menu”, under the sub-item “system”, open the “system selection” menu item
System menu
System
System selection
Boiler type
❒ In the “Boiler type” menu, select the correct option and activate the output and relevant boiler type
parameter
➥ Warning! Incorrect settings can lead to faults.
▪ PE1 Pellet 7 – 35 / PECO 15 – 35
▪ PE1e
▪ PE1c
▪ P4 Pellet 8 - 25
▪ P4 Pellet 32 – 105
❒ After selecting the actual output, the boiler specified values must be adopted
➥ Confirm the pop-up that appears with “YES”.
The boiler type parameters listed below depend on the boiler type selection previously made and must be
activated according to the system configuration.
Ignition type
Indicates which automatic ignition is being used.
Boiler heat quantity recording method
Method used for determining the quantity of heat produced by the boiler.
DHW tank system
DHW tank 01 ... 08 installed
If one or several domestic hot water tanks are installed in the hydraulic system, the respective parameter must be
activated.
Heating circuit system
Heating circuit 01 ... 18 installed
If one or several heating circuits are installed, the respective parameter must be activated.
3
Initial startup
Setting the system selection
34
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
Summary of Contents for Lambdatronic P 3200
Page 85: ...6 Notes Notes 6 Service Manual Lambdatronic P 3200 for pellet boiler 4 3 Touch B1620121_en 85...
Page 86: ...6 Notes 86 Froling GesmbH A 4710 Grieskirchen Industriestra e 12 www froeling com...
Page 87: ...Notes 6 Service Manual Lambdatronic P 3200 for pellet boiler 4 3 Touch B1620121_en 87...