Minimum value for the reload quantity
If the calculated reload quantity is less than the minimum
value setting, an instruction is displayed to the user that he
need not heat up/reload.
If the boiler is active then charge all storage tanks
Prerequisite: Variant 3 or variant 4
▪ YES: Starting the boiler due to a heating requirement by
the storage tank in the boiler system not only loads this
storage tank, but all of the storage tanks in sub-stations.
This increases the runtime related to a boiler system
start.
4.5 Boiler 2
4.5.1 Boiler 2 - Status
System menu
Boiler 2
Temperature of secondary boiler
Display of the current boiler temperature of the secondary
boiler.
Burner relay status
Shows the current status of the burner relay:
▪ 0: Secondary boiler not active
▪ 1: Secondary boiler active
Standby boiler pump
Prerequisite: “
Switch valve installed
” parameter
set to “NO”
Display of the current pump control for the standby boiler.
Standby boiler switch valve
Prerequisite: “
Switch valve installed
” parameter
set to “YES”
Display of the current switch valve control of the standby
boiler.
Manual start of secondary boiler (only when ID fan is
switched off)
▪ OFF: Secondary boiler is controlled according to the
program that is set
▪ ON: Secondary boiler is activated immediately
NOTICE! Burner blockage noted.
4.5.2 Boiler 2 - Temperatures
System menu
Boiler 2
Secondary boiler start delay
If there is a requirement from the heating circuit or DHW
tank and the buffer tank or boiler has insufficient
temperature, the secondary boiler starts after the specified
delay time set here.
Disable startup delay in case of fault?
Indicates whether the startup delay is ignored in the event
of a boiler fault and whether the standby boiler is activated
immediately on request.
Deactivate startup delay when boiler is switched off?
Indicates whether the startup delay is ignored when the
boiler is switched off and whether the standby boiler is
activated immediately on request.
Secondary boiler start, if buffer tank top temperature is
below
If the temperature in the top part of the buffer tank falls
below the specified value, the secondary boiler is started
once the set duration has elapsed.
Parameters overview
4
Boiler 2
Service Manual Lambdatronic P 3200 for pellet boiler (4,3" Touch) | B1620121_en
53
Summary of Contents for Lambdatronic P 3200
Page 85: ...6 Notes Notes 6 Service Manual Lambdatronic P 3200 for pellet boiler 4 3 Touch B1620121_en 85...
Page 86: ...6 Notes 86 Froling GesmbH A 4710 Grieskirchen Industriestra e 12 www froeling com...
Page 87: ...Notes 6 Service Manual Lambdatronic P 3200 for pellet boiler 4 3 Touch B1620121_en 87...