4 Parameters overview
4.1 Heating
4.1.1 Heating - Status
System menu
Heating
Heating circuit mode
Display and setting the heating circuit mode:
Auto:
Automatic: heating phases according to the set
heating times
Extra heating:
Heating circuit is activated for 6 hours
Setback:
Setback mode; the current or next heating phase is
ignored
Continuous setback mode:
Heating circuit remains in setback mode until
another mode is activated
Party:
Party mode; the current or next setback phase is
ignored
OFF:
Switched off; heating circuit deactivated, only frost
protection!
Actual flow temperature
Display of the current flow temperature.
Flow temperature setpoint
Display of the calculated flow temperature setpoint.
Room temperature
Prerequisite: Heating circuit used in conjunction with
remote control
Display of the current room temperature.
Outside air temperature
Display of the current outside air temperature.
Parameters overview
4
Heating
Service manual Lambdatronic SP 3200 for dual fuel boiler | B1460720_en