❒ Insert the air flaps on the pneumatic rods on the left side and secure them with
split pins
➥ CAUTION: The air flaps must be situation in the same position as those on the
opposite side!
❒ Turn both pneumatic rods in an anti-clockwise direction as far as the stop
4.5.5 Final steps before insulating
❒ Seal and screw in the immersion sleeve for thermal discharge safety device sen‐
sor
❒ Detach blanking plate for the side cleaning port
❒ Remove the screw cap from the side on which the WOS lever will be mounted lat‐
er and replace it with a brass bushing
➥ Tighten the brass bushing with Allen wrench (27 mm)
❒ Seal the broadband probe connection with a 3/4" blanking plug (2)
➥ On the S3 Turbo with S-Tronic Lambda, the broadband probe will be mounted
here later
Only for S-Tronic
and S-Tronic Plus:
4
Assembly
Installing the boiler
38
Froeling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.at
All manuals and user guides at all-guides.com