4.4 Heat up firewood manually
r
Open the insulated door and the fuel loading door
r
Check the ash level in the combustion chamber and empty if necessary
Ä
It is recommended that you do not remove the ash in the combustion chamber
during each heating-up process, but rather when the middle row of holes of the
combustion chamber guards is no longer visible. This protects the combustion
chamber.
r
Insert one layer of firewood
Ä
Use firewood with a length of approximately 50 cm and arrange it lengthwise
Ä
Do not completely cover the flame slot (A).
r
After the first layer of wood, lay cardboard across the whole area
r
Fill the fuel loading chamber according to the expected consumption and close the
fuel loading chamber door
"Determining the right amount of fuel" [
r
Open the pre-heating door, insert scrunched up paper and light
If the underpressure from the induced draught fan is too strong for the firing material to be
ignited:
r
Tap “ID fan off”
Ä
The induced draught fan switches off
r
Light the firing material
r
Tap “ID fan on”
Ä
The induced draught fan switches on