4 | Operating the System
32
B1510622_en | Operating instructions Firewood boiler S4 Turbo
4.6 Operate the boiler using the touch display
4.6.1 Overview of the touch display
A
Display of freely selectable information
"Select information displays" [
W
Display and switch the current user level
"Lock display/switch user level" [
C
Display and change the current date/time
D
Holiday program
"Configure the holiday program" [
E
Chimney sweeper function
"Emissions measurement by chimney sweep or regulatory body" [
F
Display of the current operating status
G
View available functions in the quick menu
H
Access all system information. No parameters may be changed in the info menu.
I
System menu for opening the system settings. All parameters can be displayed and/or
edited depending on the user level
"Navigation within the system menu" [
J
Display and change the current boiler mode
K
Display icons for using froeling-connect
"Display icons for froeling-connect/remote control" [
L
Brightness sensor for automatically adjusting the brightness of the display
M
Status LED to display the current system status