Servicing the system | 5
B1510622_en | Operating instructions Firewood boiler S4 Turbo
61
ca.
20 mm
r
Undo the tension springs on the top and remove the thermal insulation
r
Release the retaining screw and remove the flue gas temperature sensor from the flue
gas pipe
r
Wipe the flue gas temperature sensor with a clean cloth
r
Push in the flue gas temperature sensor until about 20 mm of the sensor remains
protruding from the bushing and secure with fixing screw
Cleaning the flue gas pipe
Switch off the induced draught fan
This prevents damage to the fan by the cleaning brush
r
Remove the inspection cover on the connecting pipe
r
Clean the connecting pipe between the boiler and chimney with a chimney sweeping
brush
Ä
Depending on how the flue gas pipes and chimney draught are installed, adjust the
cleaning intervals according to the degree of soiling
Checking the draught controller flap
r
Check that the draught controller flap moves freely