Servicing the system | 5
B1510622_en | Operating instructions Firewood boiler S4 Turbo
63
Checking the seal on the doors
Checking the tightness is shown below using the example of the fuel loading door and is
carried out in the same way for the other boiler doors.
On the door stop side and door handle side:
r
Open the door and insert a sheet of paper at both the top and the bottom of the door
stop between the door and the boiler
r
Close the door and try to pull out the sheets of paper
Ä
If the paper can be removed:
door is not sealed properly and must be adjusted!
Adjusting the doors
r
Loosen the locknuts (A – AF 13) on the locking cams
r
Press door onto door frame and adjust the contact pressure using the locking cam (B)
Ä
Adjusting spanner (C) included!
Ä
CAUTION: The hinge must be aligned in the same way at the top and bottom
r
Secure the adjustments by tightening the lock nuts (A)