5.5.3 Network
System menu
PLC
Network
Obtain IP address automatically
▪ YES: The address in the local network (IP address), the
subnet mask and default gateway are automatically
assigned by the router/server
▪ NO: The address in the local network (IP address), the
subnet mask and default gateway must be manually
specified
Hostname
Name of the SPS or wood gasifier in the local network.
VNC
▪ YES: Activate integrated VNC server. Connections with
a suitable VNC client are possible.
▪ NO: Do not activate the VNC server. External
connections are only possible with the Froling
Visualisation Software.
5.5.4 Log file
System menu
PLC
Log file
Logging level
Defines the level of detail when writing the log file.
Changes may only be made if necessary and after
consultation with Froling.
Log in file
To enable/disable the logging (recording) in a log file.
5.5.5 Touchscreen & operation
Settings
System menu
PLC
Touchscreen
Settings
Screensaver delay
If there is no operation on the touch panel of the PLC
within this time, the screen saver is activated.
Automatic logout
Defines how long the set operator level remains active
during a period of inactivity. If the display is not operated
within this time, the SPS will automatically switch back to
the customer level.