Rotary agitator with separate drive system (optional)
In the case of rotary agitators with a separate drive system, the head of the rotary
agitator can be operated separately from the discharge screw.
After working in the store:
❒ Turn on the boiler’s main switch
❒ Turn on the main switch on the expansion switch cabinet (if installed)
❒ Tap “Manual” in “Bunker filling rotary agitator” during manual operation
➥ The rotary agitator runs for approx. 3 minutes
❒ Wait until the rotary agitator arms / spring blades are touching the head of the
rotary agitator (approx. 2 revolutions)
❒ Close all openings to the store to seal out dust
❒ Add the rest of the fuel
3.2.5 Blowing in pellets for a store with pellet screw
❒ Switch off the boiler by tapping “Boiler off” at the mode icon and allow to cool for at
least two hours
❒ Close all openings to the store to seal out dust
❒ Blow the fuel into the store
3.2.6 Loading fuel in a store space with a sliding floor discharge unit
❒ The maximum dumping height (depending on the fuel density) as specified in the
operating instructions for the sliding floor must not be exceeded.
❒ Driving over the fuel in the store can cause the material to be compacted.
➥ This may stop the slide rods from running smoothly.
Filling the store by driving over the slide rods
Slide rods can be driven over, provided the following precautions are taken:
❒ The slide rods must be covered by a residual fuel layer approx. 30 cm deep so
that the truck does not drive directly over the sliding floor keyways.
❒ On no account may the truck drive over the longitudinal support for the slide rods.
(Provide guidance systems for driving the truck into the store, or position gates
appropriately)
❒ While the truck is on the sliding floor, the hydraulic unit must be switched off
❒ While it is on the sliding floor the truck should be manoeuvred as little as possible
Filling the store by tipping fuel onto or next to the slide rods
❒ If the fuel can be tipped out without driving over the slide rods, the store can be
filled while the boiler is running
Operating the system
3
Filling the store space with fuel
Operating Instructions | B1300015_en
29