1. Open the combustion chamber door
2. Carefully clean the bottom of the upper vault and the top of the lower vault with the
cleaning brush
3. Carefully clean the side walls with the flat scraper
4. Open the burning chamber door
5. Carefully clean the bottom of the lower vault with the cleaning brush
6. Carefully clean the side walls with the flat scraper
7. Check the fireclay elements for wear
8. Remove any ash which has gathered.
9. Close all doors again
4.6.7 Checking the underpressure controller
(Pos. L
⇨ See "Periodic inspection and cleaning" [page 42]
)
❒ Disconnec the silicone hose from the differential pressure transducer
❒ Using compressed air, blow out the hose in the direction of the combustion space
to remove any deposits
❒ Connect the silicone hose to “Minus”
Servicing
4
Periodic inspection and cleaning (approx. 3,000 hrs)
Operating Instructions | B1300015_en
51