Installation location and position
Selecting a loca-
tion
Please observe the following criteria when choosing a location for the inverter:
The inverter is suitable for indoor installation.
The inverter is suitable for outdoor installation.
Because of its NEMA4X protection class, the inverter is not sus-
ceptible to hose water on any side and can also be operated in
moist environments.
In order to keep inverter heating as low as possible, do not expose
the inverter to direct sunlight. The inverter should be installed in a
protected location, e.g., near the solar modules or under an over-
hanging roof.
Altitude above sea level: up to 11,482 ft. (3500 m)
IMPORTANT!
The inverter must not be installed or operated
above an altitude of 11,482 ft (3500 m).
The max. permissible DC voltage of the inverter depends on the
altitude:
-
0 - 6561 ft. (0 - 2000 m) ... U
DC max
= 550 V
-
> 6561 - 8202 ft. (> 2000 - 2500 m) ... U
DC max
= 540 V
-
> 8202 - 9842 ft. (> 2500 - 3000 m) ... U
DC max
= 480 V
-
> 9842 - 11,482 ft. (> 3000 - 3500 m) ... U
DC max
= 430 V
The output power reduces when the device temperature is too
high, and this may occur earlier than normal at increased alti-
tudes.
NH
3
Do not install the inverter:
-
Where it may be exposed to ammonia, corrosive gases, acids,
or salts
(e.g., fertilizer storage areas, vent openings for livestock
stables, chemical plants, tanneries)
8
Summary of Contents for 1.5-1
Page 2: ......
Page 12: ...12 ...
Page 13: ...Preparation 13 ...
Page 14: ...14 ...
Page 21: ...AC 21 ...
Page 22: ...22 ...
Page 30: ...30 ...
Page 31: ...DC 31 ...
Page 32: ...32 ...
Page 41: ...2 2 1 max 0 28 in 7 mm 8 Fit the padlock to the anti theft device 41 EN US ...
Page 49: ...49 EN US ...
Page 50: ...50 ...
Page 51: ...51 EN US ...
Page 52: ... ...