53
EN-US
Visual inspection
General
During a visual inspection, the tests described below are to be carried out without further
dismantling of the equipment. Safety related parts must not show any visible defects. Fur-
thermore, defects which may present a danger during the visual inspection must be written
down.
Deficiencies identified that may be the cause of other hazards must be repaired immedi-
ately, otherwise further use must be restricted until the defect is rectified.
Mains Power Sup-
ply and Connec-
tion Cables
-
Connection cables and external leads must not be damaged or defective.
-
Insulation must not be defective (do not use insulation or adhesive tape to repair dam-
age).
-
Plugs and plug connections must not be damaged or deformed.
-
Strain relief devices, bend radius protection devices, conduits and fixings must be ef-
fective.
-
Cables/plugs must be suitable for their area of application and power.
-
Fuse links and device fuse holders must not be defective.
Housing and Cov-
ers
-
Housing, insulation items and protective covers must not be missing or damaged.
-
Unauthorized modifications must not be present, e.g.: Fittings and modifications not
authorized by the manufacturer.
-
Ventilation openings must not be soiled or blocked, air filters must be present.
-
There must be no sign of soiling, corrosion or degradation that would compromise
safety.
-
Indications of overload and improper use must not be present.
-
Conductive objects must not be inside the housing.
Adjustment and
display devices
-
Control elements and indicators must not be faulty
Rating Plate and
Warning Stickers
-
Safety-related labels must be present, e.g.: Warning notices, grounding symbols, and
rating plates. If necessary, renew, add to or correct the labels in a suitable form.
-
Ensure that all safety-related labels or symbols, rated values and position indicators
are legible.
IMPORTANT!
To determine the cross-section and current carrying capacity of mains ca-
bles, observe standard IEC 60364-5-52. As the current carrying capacity can vary due to
the cable layout and its insulation and differing ambient temperatures, when the mains
leads are replaced the requirements of standard IEC 60364-5-52 must be met. Individual
national requirements and standards must also be observed.
Summary of Contents for Eco 15.0-3-208 US
Page 2: ...2...
Page 4: ...4...
Page 5: ...Allgemeine Informationen...
Page 6: ......
Page 8: ...8 Mess und Pr f mittel Digitales Multimeter Equipment f r die sicherheitstechnische berpr fung...
Page 9: ...Einbau State 112 KIT...
Page 10: ......
Page 15: ...15 DE 1 2 3 4 5 1 2 3 4 22 1 lbf in 2 5 Nm 5...
Page 19: ...Sicherheitstechnische berpr fung...
Page 20: ......
Page 32: ...32...
Page 34: ...34...
Page 35: ...General Information...
Page 36: ......
Page 38: ...38 Measuring and In spection Equip ment Digital multimeter Equipment for safety inspection...
Page 39: ...Installation State 112 KIT...
Page 40: ......
Page 45: ...45 EN US 1 2 3 4 5 1 2 3 4 22 1 lbf in 2 5 Nm 5...
Page 49: ...Safety inspection...
Page 50: ......
Page 62: ...62...
Page 63: ...63 EN US...