28
Every start-up
-
Check welding torch, interconnection cable assembly and bondings for damage
-
Check whether the allround distance of 0.5 m (1.6 ft.) is kept to ensure that the cooling
air can easily flow and escape.
NOTE!
Furthermore, air inlets and outlets must in no case be covered, not even covered
partly.
CAUTION!
Danger of scalding from hot coolant fluid.
Do not inspect the coolant connection points until the coolant has been allowed to cool.
If water-cooled welding torch is used:
-
Check water connections for tightness
-
Control water return flowrate in coolant container
-
If there is no water return flow, check cooling unit and purge if necessary
NOTE!
If water-cooled welding torches are operated without cooling water, this mostly
causes a defect of the torch body or the hose pack.
The manufacturer does not accept responsibility for any consequential damages. Any war
-
ranty claims expire.
Every week
Check the coolant level as well as the coolant purity.
If the coolant level drops below the “min“ mark ... refill coolant.
Every 2 months
Check the coolant level as well as the coolant purity.
If the coolant level drops below the “min“ mark ... refill coolant.
Every 6 months
Dismantle machine side panels and clean machine inside with dry reduced com
-
pressed air
NOTE!
Risk of damage to electronic components.
Clean electronic components from a certain distance only.
Clean also the water coolers in the case of excessive dust
1
2
1
2
1
1