56
Controls and indicators
Controls and indi-
cators
Item
Description
(1)
Display
for displaying values, settings and menus
Monitoring and status LEDs
(2)
General status LED (red)
on steady
-
if a status message is being displayed on the monitor
-
if the process of feeding energy into the grid is interrupted
-
while error handling (the inverter waits for an acknowledgement or for an
error to be rectified)
(3)
Startup LED (orange)
on steady if
-
the inverter is in its automatic startup or self-test phase (as soon after sun-
rise as the solar modules are delivering sufficient power)
-
the inverter has been switched to standby mode in the setup menu (= feed-
ing energy into the grid switched off manually)
-
the inverter software is being updated
(4)
Operating status LED (green)
on steady,
-
if the PV system is working correctly after the inverter's automatic startup
phase
-
all the time while energy is being fed into the grid
Function keys - allocated different functions depending on the selection:
(5)
'Left/up' key
for navigating to the left and up
(6)
'Down/right' key
for navigating down and to the right
(7)
'Menu/Esc' key
for switching to the menu level
for quitting the setup menu
(8)
'Enter' key
for confirming a selection
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)