69
EN
Status LT
The status display of the most recent inverter fault can be displayed.
IMPORTANT!
Due to the low level of insolation early in the morning and in the evening,
the status codes 306 (Power low) and 307 (DC low) are displayed routinely at these times
of day. These status messages do not indicate any kind of fault.
-
Press the 'Enter' key to see the status of the power stage set and the most recent fault
-
Use the 'Up' and 'Down' keys to scroll through the list
-
Press the 'Back' key to close the status and fault list
Grid Status
The five most recent grid faults can be displayed:
-
Press the 'Enter' key to see the five most recent grid faults
-
Use the 'Up' and 'Down' keys to scroll through the list
-
Press the 'Back' key to close the grid fault display
Fan test
To check that the fan is working correctly
The fan test is started by pressing the 'Enter' key.
While the test is ongoing, its ' Progress' is shown on the display.
OK
Fan test successful
Fail
Fan is defective; the associated status code is displayed in 'NOW' view mode.
Version
Displays the version and serial numbers of the PC boards in the inverter (e.g. for service
purposes)
Unit
-
Setting range
Start (Progress)
Factory setting
-
Unit -
Display area
Display / Display Software / Interface / SmartMedia Card / Con-
trol / Control Software / Monitoring / Monitoring Software / Inter-
face
Factory setting
-