127
Class 4 Status
Codes
(continued)
465
Display error
The UI command sent from the IG Brain is not recognized by the present
display version.
Behavior
The Fronius IG Plus stops feeding power into the
grid, the display shows a critical error via a red Ope-
rating Status LED
Remedy
If status code persists, contact a Fronius-trained
service technician
466
Display error
The display was not detected.
Behavior
The Fronius IG Plus stops feeding power into the
grid, the display shows a critical error via a red Ope-
rating Status LED
Remedy
Check the display for damage, connect display, check
ribbon wire for damage, check IG Brain for damage
If status code persists, contact a Fronius-trained
service technician
467
The display has not received a start command from the IG Brain for lon-
ger than 6 s
Behavior
The Fronius IG Plus will automatically attempt to
connect again and, if possible, resume feeding power
into the grid
Remedy
If status code persists, contact a Fronius-trained
service technician
469
Throttle connected to wrong poles
Behavior
The Fronius IG Plus stops feeding power into the
grid, the display shows a critical error via a red Ope-
rating Status LED
Remedy
Properly connect throttle
If status code persists, contact a Fronius-trained
service technician
470
The buck converter relay does not open at high DC voltage
Behavior
The Fronius IG Plus stops feeding power into the
grid, the display shows a critical error via a red Ope-
rating Status LED
Remedy
Check system configuration
If status code persists, contact a Fronius-trained
service technician
472
Ground fault detected
Behavior
Inverter is blocked from feeding energy into the grid
Remedy
Change GFDI fuse
Summary of Contents for IG Plus 12.0-3
Page 2: ......
Page 4: ...ud_fr_st_et_01382 012008...
Page 6: ......
Page 16: ...6...
Page 17: ...7 General Information...
Page 18: ...8...
Page 24: ...14...
Page 25: ...15 Installation and Startup...
Page 26: ...16...
Page 80: ...70...
Page 81: ...71 Operation...
Page 82: ...72...
Page 122: ...112...
Page 123: ...113 Troubleshooting and Maintenance...
Page 124: ...114...
Page 149: ...139 Appendix...
Page 150: ...140...