37
EN
The wire moves backwards at the specified wire speed for as long as the "Wire retract" sig-
nal is set.
IMPORTANT!
It is not possible to send a command to the KD 7000 using the "Start KD" or
"Robot wire-pulsing" signals while the "Wire retract" signal is enabled.
"Wire retract" is different to the "Wire retract on/off" signal, which disables automatic wire
retraction at the end of welding.
Robot wire-puls-
ing (Wire pulse
robot)
TIG-KD connection box:
Connection option direct to the KD 7000:
The "Wire pulse robot" signal sets pulsing of the cold wire by the robot control.
-
"Puls Robot" mode must have been selected on the "Wire-Mode" dip switches.
-
The wire speed switches between 0 and the entered set value, according to the signal
for pulsing.
-
24 V set ==> wirefeeding stops
-
24 V missing ==> wirefeeding at set wire speed value
IMPORTANT!
If "Puls Synch Tig" mode has been selected on the "Wire-Mode" dip switch-
es,
-
it is not possible to send a command to the KD 7000 via the "Wire pulse robot" signal,
-
pulsing of the cold wire is set by the power source.
The wire speed switches between 0 and the entered set value, synchronous with puls-
ing of the welding current.
Plug X3/pin 36
24 V
Plug X3/pin 27
GND
Plug X2/pin 24
24 V
Plug X2/pin 27
GND
Summary of Contents for KD 7000
Page 2: ...2...
Page 4: ...4...
Page 30: ...30 TIG KD connection box wiring diagram...
Page 32: ...32 KD 7000 wiring diagram...
Page 45: ...45 EN 3 Inserting the wire spool 1 1 2 3 1 2 3 1...
Page 52: ...52 Spare parts list KD 7000...
Page 57: ...57...
Page 58: ...58...