39
EN
Select simulation of TR 55 r remote control on the "Remote Control" dip switches (see
"TIG-KD connection box").
TIG-KD connection box:
IMPORTANT!
Frequency range switchover takes place in 0.8 V steps.
Connection option direct to the KD 7000:
A voltage of 0 - 10 V is specified for the set values for the listed welding parameters.
0 V ........ Minimum parameter set value
10 V ...... Maximum parameter set value
Plug X3/pin 1
Main current or pulse current (+ 0 to + 10 V)
Plug X3/pin 4
AC balance (MagicWave only) (+ 0 to + 10 V)
Plug X3/pin 9
Base current (+ 0 to + 10 V)
Plug X3/pin 10 frequency range switchover (+ 0 to +10 V)
Plug X3/pin11
Pulse frequency (+ 0 to + 10 V)
Plug X3/pin 12
Pulse width (+ 0 to + 10 V)
Plug X3/pin 6
GND
Plug X2/pin 17
24 V
Plug X2/pin 27
GND
Summary of Contents for KD 7000
Page 2: ...2...
Page 4: ...4...
Page 30: ...30 TIG KD connection box wiring diagram...
Page 32: ...32 KD 7000 wiring diagram...
Page 45: ...45 EN 3 Inserting the wire spool 1 1 2 3 1 2 3 1...
Page 52: ...52 Spare parts list KD 7000...
Page 57: ...57...
Page 58: ...58...
Page 59: ...59...