136
Replacing the PrimoPS power PC board
Preparatory work
Set the DC disconnector to OFF
Disconnect the AC supply
Remove the DATCOM cover
Disconnect the data communication cables if necessary
Release the device from the wall bracket and remove.
Remove the power stage set cover
Replacing the Pri-
moPS power PC
board
Removing the PrimoPS:
Remove air guide (1).
Disconnect all the cables (2) - (4) from
the PrimoPS
Remove the 14 4x9 mm TX20 screws
(5) from the PrimoPS PC board
Feed the LVRT cable out of the ferrite
ring
WARNING!
An electric shock can be fatal.
Follow the five safety rules.
1
2
3
4
5
6
(1)
1
(2)
(3)
(4) (5)
(5)
(5)
(5)
(5)
2
3
4
Summary of Contents for Primo 3.0-1