230
Feeder creep speed
for setting the speed of the wire feeder creep (characteristic parameters)
Unit
[m/min]
Range
0.5 - max.
Final current Ie
for setting the final current so that
a) heat build-up towards the end of welding is prevented and
b) the end-crater is filled (in the case of aluminium)
(I-E)
Unit
[%]
Range
0 - 200
Final-current duration te
for setting the linear current decrease rate following the boost phase
for CMT Advanced characteristics
(t-E)
Unit
[s]
Range
Off/0.1 - 9.9
Firewall IP
for assigning access rights to a specific power source for all comput-
ers on a local network
Unit
-
Range
0 - 255 (per item)
Flow watchdog filter time
for presetting the time from when the flow watchdog is triggered until the "no | H2O" ser-
vice code is output
Unit
[s]
Range
5 - 25
Frequency
for setting the frequency for SynchroPulse
(F)
Unit
[Hz]
Range
Off/0.5 -10
Gas factor
for setting the correction factor when a different shielding gas is used
for the selected filler metal than the one programmed at the factory
(only where "Digital Gas Control" option is available)
(Cor)
Unit
-
Range
Auto/1 - 10
Gas post-flow
for setting the gas post-flow time after the arc has extinguished
(GPo)
Unit
[s]
Range
0 - 9.9
Gas pre-flow
for setting the gas flow time before the arc is ignited
(GPr)
Unit
[s]
Range
0 - 9.9
Gas set value
for setting the set value for gas flow
(GAS)
Unit
[l/min]
Range
OFF/5 - 30
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...