235
EN
Maximum duration of wire feed speed deviation
for setting the maximum duration of a wire feed speed deviation
Unit
[s]
Range
Off/0.1 - 9.9
Maximum main motor current
for setting the maximum permitted motor current on the main wire-feed unit
Unit
[A]
Range
0.0 - 9.9
Maximum PPU motor current
for setting the maximum permitted motor current on a push-pull unit
Unit
[A]
Range
0.0 - 9.9
Mean wire feed speed
refers to the specified value for wire feed speed (see also wire feed speed)
Unit
[m/min]
Range
min. - max.
Month
for presetting the month in the date display
Unit
-
Range
January - December
N_CMT_Cycles
number of CMT cycles with CMT Advanced Pulse characteristics
Unit
-
Range
-
N_Puls_Cycles
number of pulsed cycles with CMT Advanced Pulse characteristics
Unit
-
Range
-
Negative_weldstart_cycles
Number of negative weld start cycles
Unit
-
Range
-
Part number
for specifying the part number
Unit
-
Range
Any alphanumeric expression with a maximum length of 20 characters
Part number counter
for activating the part counter function
Unit
-
Range
Off/On
Polarity
for setting the polarity for MMA welding
Unit
-
Range
Plus/minus
Positive_weldstart_cycles
Number of positive weld start cycles with CMT Advanced characteristics
Unit
-
Range
-
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...