238
Subnet mask
Network-specific parameter of a local network; allocated on-site by the relevant network
administrator
Unit
-
Range
0 - 255 (per item)
Summary_weldstart_cycles
Total number of weld start cycles
Unit
-
Range
-
t_base
for setting the length of time that the current command value is active in the base current
phase for CMT/pulse characteristics
Unit
[ms]
Range
0.00 - 99.98
t_burnback
for setting the duration of the currentless wire retract after the welding current has been
switched off
Unit
[ms]
Range
0.00 -200.02
t_hotstart
for setting the length of time that the change in the arc length is active when welding be-
gins
Unit
[ms]
Range
0.00 - 654.98
t_I_boost
for setting the duration of the boost phase (how long the current command value is active
in the boost phase)
Unit
[ms]
Range
0.00 - 99.98
t_ignition
for setting how long the ignition current and the wire feed speed are active before the start
of welding
Unit
[ms]
Range
0.00 - 99.98
t_p1
for setting the pulse current phase for CMT/pulse and CMT Advanced Pulse characteris-
tics
Unit
[ms]
Range
0.00 - 50.02
t_p2
the length of time the droplet-detachment current is active with CMT Advanced Pulse
characteristics
Unit
[ms]
Range
0 - 50
Current-drop (tau)
Time of transition from a linear slope to the droplet-detachment current.
Unit
[ms]
Range
0 - 5
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...