51
EN
Setting additional spot welding parameters
Setting addition-
al spot welding
parameters
If spot welding is selected as the trigger mode in the "Working parameters" screen, the cor-
responding screen is hung on the clothesline.
The following parameters can be set:
-
Wire feed speed
-
Arc length correction
-
Spot welding time
"Working parameters" screen: spot welding trigger
mode
Call up "MIG/MAG standard manual
welding" menu item
Select "Working parameters" screen
by pressing the right arrow key (8)
–
"Working parameters" screen ap-
pears
Select the "trigger mode" parameter
using the down (6) or up (7) keys
Set spot welding using adjusting dial
(18)
Select "Spot welding" screen by pres-
sing the right arrow key (8)
–
"Spot welding" screen appears
MIG/MAG synergic welding: "Spot welding" screen,
wirefeed speed selected
Select parameters using the down (6)
or up (7) keys
Change the value of the parameters
using the adjusting dial (18)
–
The value of the parameters can
only be altered within the defined
setting range. The setting range is
highlighted.
1
2
3
4
5
6
7
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...