The following jumpers are available for individual settings:
1.
„Buz.“
(on/off) ... Default setting: „on“
2.
„Err.“
(perm./all) ... Default setting: „all“
General
Jumper
1. „Buz.“ jum-
per
-
„on“ position ... A buzzer (acoustic signal)
sounds if a service code is signalled. Soun-
ding the acoustic signal also switches the
relay.
2. „Err.“ jum-
per
A. Temporary service codes:
These service codes only appear temporarily and prevent feeding
into the grid for a short time.
Example: Deactivation due to fluctuations in the mains voltage
-
The Fronius Signal Card reacts if a temporary service code occurs
more than 50 times in a single day.
B. Permanent service codes:
-
Service codes that concern at least one fault in the inverter and cau-
se it to stop (e.g. hardware fault).
-
The Fronius Signal Card reacts if a permanent service code is sig-
nalled for longer than 4:15 hours.
-
„off“ position ... Only the relay is switched if
a service code is signalled. An additional
acoustic signal is not emitted.
Buz.
off
on
Buz.
off
on
-
„all“ position ... Every service code (perma-
nent or temporary) causes the relay to
switch or the buzzer to sound.
-
„perm“ position ...Only permanent service
codes cause the relay to switch or the buz-
zer to sound.
Err.
perm.
all
Err.
perm.
all
Summary of Contents for Signal Card
Page 2: ......
Page 27: ...1 Z H ...
Page 28: ...2 ...
Page 29: ...3 Z H ...
Page 30: ...4 1 4 5 8 6 7 3 2 9 ...
Page 31: ...5 Z H 15 mm 5 mm ...
Page 32: ...6 ...
Page 33: ...7 Z H ...
Page 34: ...8 ...
Page 35: ...9 Z H ...
Page 36: ...10 Buz off on Buz off on Err perm all Err perm all ...
Page 37: ...11 Z H ...
Page 38: ......