WARNING!
An electrical shock can be fatal. Danger from DC
voltage from solar modules.
-
Make sure that the input and output sides in front of the
device are not charged before connecting anything.
-
Any and all connections should only be carried out by quali-
fied electricians.
-
Follow the safety rules in these operating instructions.
In order to select suitable solar modules and get the most efficient use out
of the inverter, please note the following points:
-
The open circuit voltage of the solar modules increases at constant
irradiance and when temperature decreases. The open circuit voltage
should never rise above the admissible inverter voltage, assuming an
irradiance of 1000 W/m² and a temperature of 14 °F (-10 °C).
Whenever the open circuit voltage of the solar modules exceeds the
admissible inverter voltage, the inverter may be damaged, and all
warranty rights will become null and void.
-
More exact data for sizing the solar array for the particular location
can be obtained using calculation tools such as the Fronius Configura-
tion Tool (available on http://www.fronius-usa.com).
-
See NEC table 690.7 for the appropriate code-related voltage adjust-
ment factor for crystalline silicon modules, or use the manufacturer’s
specified voltage coefficient.
WARNING!
An electric shock can be fatal. Inadequately sized
electrical components can cause serious injuries to persons
and damage to (or loss of) property.
-
All electrical installations must be in accordance with the
National Electrical Code, ANSI/NFPA 70, and any other
codes and regulations applicable to the installation site.
-
For installations in Canada the installations must be done in
accordance with applicable Canadian standards.
-
Use minimum AWG 12, min. 194 °F (90 °C), copper wire for
all grounding wires .
-
For appropriate grounding see NEC table 250.122.
-
Use minimum AWG 12 to maximum AWG 8, min. 194 °F
(90 °C), copper or aluminium wire for all DC wiring connec-
tions to the Fronius String Control 250/25. Voltage drop and
other considerations may dictate larger size wires be used.
-
Use only solid or stranded wire. Do not use fine stranded
wire.
Connecting Solar Module Strings to the Fronius
String Control 250/25
General Infor-
mation About
Solar Modules
Safety