17
EN-US
(2)
WLAN LED
-
Flashes green: Fronius Datamanager 2.0 is in service mode
(IP switch on the Fronius Datamanager 2.0 plug-in card is set to position A or
service mode was activated via the inverter display, the WLAN Access Point is
opened)
-
Lights up green: There is an existing WLAN connection
-
Alternately flashes green/red: The length of time for which the WLAN Access
Point is open after activation (1 hour) has been exceeded
-
Lights up red: There is no existing WLAN connection
-
Flashes red: Faulty WLAN connection
-
Does not light up: Fronius Datamanager 2.0 is in slave mode
(3)
Fronius Solar.web connection LED
-
Lights up green: There is an existing connection to Fronius Solar.web
-
Lights up red: There is no existing connection to Fronius Solar.web, but one is
required
-
Does not light up: No connection to Fronius Solar.web is required
(4)
Supply LED
-
Lights up green: Sufficient power supply from Fronius Solar Net; Fronius Data-
manager 2.0 is operational
-
Does not light up: No power or insufficient power supply from Fronius Solar Net
– an external power supply is required
or
Fronius Datamanager 2.0 is in slave mode
-
Flashes red: During an update process
IMPORTANT!
Do not interrupt the power supply during an update process.
-
Lights up red: Update process failed
(5)
Connection LED
-
Lights up green: There is an active connection within Fronius Solar Net
-
Lights up red: There is an interrupted connection within Fronius Solar Net
-
Does not light up: Fronius Datamanager 2.0 is in slave mode
(6)
LAN connection socket
Ethernet interface colored blue for connecting the Ethernet cable
(7)
I/Os
Digital inputs and outputs
Modbus RTU 2-wire (RS-485):
D-
Modbus data -
D+
Modbus data +
No. Function
D-
-
-
1
3
5
7
9
D+
+
+
0
2
4
6
8
I IO RS485