34
To deactivate the "Energy Manager" function, select another function and press the "Enter"
key.
Information on the Layout of the Switch-on and Switch-off Points
Insufficient difference between the switch-on point and the switch-off point or power fluc-
tuations can cause frequent switching cycles.
To avoid excessive switching on and off, the difference between the switch-on and switch-
off points should be at least 100–200 W.
When selecting the switch-off point, consider the power consumption of the connected us-
er.
When selecting the switch-on point also bear in mind the weather conditions and the ex-
pected solar radiation.
Application Example
Switch-on point = 2000 W, switch-off point = 1800 W
If the inverter supplies 2000 W or more, the potential-free switch contact of the inverter is
switched on.
If the inverter output sinks below 1800 W, the potential-free switch contact is switched off.
Possible applications:
Operation of a heat pump or air-conditioning system, using as much self-produced power
as possible.
Time/Date
Setting the time, date and automatic adjustment for daylight saving time
To activate the "Energy Manager" function, select "E-manager" and press the "Enter" key.
When the "Energy Manager" function is activated, the "Energy Manager" icon is dis-
played at the top left of the display:
When potential-free NO switch contact is switched off (open contact)
When potential-free NO switch contact is switched on (closed contact)
Setting range
Set time / Set date / Time display format / Date display format /
Daylight saving time
Set time
Setting the time (hh:mm:ss or hh:mm am/pm, depending on the setting under Time dis-
play format)
Set date
Setting the date (dd.mm.yyyy or mm/dd/yyyy, depending on the setting under Date dis-
play format)
Time display format
For specifying the format in which the time is displayed
Setting range
12 hrs / 24 hrs
Factory setting
depends on the country setup
Date display format
For specifying the format in which the date is displayed
Setting range
mm/dd/yyyy / dd.mm.yy
Factory setting
depends on the country setup