The Basic menu contains the following parameters important for the installation and op-
eration of the inverter:
MPP Tracker 1 / MPP Tracker 2
-
MPP Tracker 2: ON / OFF (for MultiMPP Tracker devices only, except Fronius Symo
15.0-3 208)
-
DC operating mode: MPP AUTO / FIX / MPP USER
-
MPP AUTO: normal operating status; the inverter automatically searches for the
optimal operating point
-
FIX: enter a fixed DC voltage used by the inverter
-
MPP USER: enter the lower MPP voltage from which the inverter searches for
its optimal operating point
-
Dynamic Peak Manager: ON/OFF
-
Fixed voltage: enter the fixed voltage
-
MPPT start voltage: enter the start voltage
USB Logbook
Activate or deactivate the function for saving all error messages to a USB flash drive
AUTO / OFF / ON
Signal Input
-
Function: Ext Sig. / S0-Meter / OFF
for Ext Sig. function only:
-
Trigger type: Warning (warning shown on the display) / Ext. Stop (inverter is
switched off)
-
Connection type: N/C (normally closed) / N/O (normally open)
SMS/Relay
-
Event delay
for entering the delay time after which an SMS text message is sent or the relay
should switch
900–86400 seconds
-
Event counter:
for entering the number of events that lead to a signal:
10 - 255
Isolation Setting
-
Isolation warning: ON/OFF
-
Threshold warning: enter a threshold value that would trigger a warning
TOTAL Reset
resets the max. and min. voltage values and the max. power of feeding in to zero in the
LOG menu.
Once values are reset, this action cannot be undone.
To reset the values to zero, press the "Enter" key.
"CONFIRM" is displayed.
Press the "Enter" key again.
The values are reset and the menu is displayed