8
Only operate the device when all protection devices are fully functional. If the
protection devices are not fully functional, there is a risk of
- injury or death to the operator or a third party,
- damage to the device and other material assets belonging to the operator,
- inefficient operation of the device.
Any safety devices that are not functioning properly must be repaired before
switching on the device.
Never bypass or disable protection devices.
Before switching on the device, ensure that no one is likely to be endange-
red.
-
Check the device at least once a week for obvious damage and proper
functioning of safety devices.
-
Only use suitable original cutting medium from the manufacturer.
-
Always check the cutting medium level before you start cutting.
Safety measures
in normal mode
It is impossible to guarantee that bought-in parts are designed and manufac-
tured to meet the demands made on them, or that they satisfy safety require-
ments. Use only original replacement and wearing parts (also applies to
standard parts).
Do not carry out any modifications, alterations, etc. without the
manufacturer’s consent.
Components that are not in perfect condition must be changed immediately.
When ordering, please give the exact designation and part number as shown
in the spare parts list, as well as the serial number of the device.
Maintenance and
repair
Safety measures
at the installation
location and
during transport
A device that topples over can easily kill someone. Place the device on a
solid, level surface. The maximum permissible slope is 10°.
Special regulations apply in rooms at risk of fire or explosion. Observe
relevant national and international regulations.
Use internal directives and checks to ensure that the workplace environment
is always clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protec-
tion shown on the rating plate.
When setting up the device, ensure there is a gap of 0.5 m (1.6 ft.) all round
so that cooling air can enter and exit unhindered.
When transporting the device, observe the relevant national and local guideli-
nes and accident prevention regulations. This applies especially to guidelines
regarding the risks arising during transportation.
After transporting the device, and before commissioning, you MUST carry out
a visual inspection to check whether it has been damaged in any way. Any
damage must be repaired by trained service personnel before commissio-
ning takes place.