14
Before commissioning
WARNING!
Operating the equipment incorrectly can cause serious injury and
damage. You should not use the functions described until you have thoroughly
read and understood the following documents:
-
These operating instructions
-
All the operating instructions for the system components, especially the
safety regulations
WARNING!
A machine that topples over or falls from its stand can easily kill
someone. Place machine on a solid, level surface in such a way that it re-
mains stable.
Setup regulations
Mains connection
The device is designed to run at the mains voltage indicated on the rating plate. The
required mains supply fuse protection can be found in the „Technical data“ section.
If there is no network cable or mains plug on your machine, fit a network cable or plug
according to the national standards.
NOTE!
Inadequately dimensioned electrical installations can lead to serious
damage. The mains lead, and its fuse protection, must be dimensioned in
accordance with the local power supply. The technical data shown on the rating
plate shall apply.
The device is designed exclusively for plasma cutting.
Utilisation for any other purpose, or in any other manner, shall be deemed to be „not in
accordance with the intended purpose“. The manufacturer shall not be liable for any
damage resulting from such improper use.
Utilisation in accordance with the „intended purpose“ also comprises
-
Following all the instructions given in this manual
-
Performing all stipulated inspection and servicing work.
The device must only be used in combination with the CTW 300 plasma cutting torches.
Utilisation in
accordance with
„intended purpo-
se“
General remarks
The power source is tested to IP 23S, meaning:
-
protection against ingress of solid bodies with diameters greater than 12.5 mm (.49
in.)
-
protection against direct sprays of water up to 60° from the vertical
You can therefore set up and operate the device outdoors in accordance with IP 23S. If it
is raining or snowing, however, the machine must not be used. Built-in electrical parts
must be protected from direct wetting.
The device is completely generator-compatible, provided the maximum apparent power
delivered by the generator is at least 8 kVA.
NOTE!
The voltage supplied by the generator must never rise above or fall
below the mains voltage tolerance specified in the Technical data chapter.
Generator-
powered operati-
on
Summary of Contents for TransCut 300
Page 2: ......
Page 4: ......
Page 14: ...10 ...
Page 28: ...24 ...
Page 31: ...TransCut 300 plasma cutting device ...
Page 32: ...TransCut 300 cutting torch ...